Palm Bay Utilities Department Policies, Procedures & Standards Handbook
The Palm Bay Utilities Department has developed a Policies, Procedures & Standards Handbook for contractors, developers, etc. that may need specific details and information regarding the standard guidelines for our system. The information in this document along with the City of Palm Bay Land Development Code is intended to provide minimum standards for approving design and construction of water, wastewater and reclaim facilities, transmission, collection and distribution systems.
Standards Manual
The Standards Manual requires Adobe Acrobat for viewing. Click on the icon to download for free.

Section 10 - Standard Drawings
To view the following Details/Drawings from the Standards Manual you will need to have AutoCad installed on your computer, or you can download a free AutoCad Viewer.
Click here to download a free viewer. (This is a very large file and may take a considerable amount of time to download.)
For your convenience you can also download the zip file below to quickly save the files to your desktop. You will need Winzip installed on your computer, or you can download for free. Click here to download a free version.
Download Zip File of Drawings
| Figure |
| 1 |
Excavation and Backfill for Utilities Pipe |
| 1-2 |
Excavation and Backfill for Utilities Pipe (Page 2) |
| 1-3 |
Excavation and Backfill for Utilities Pipe (Page 3) |
| 2 |
Concrete Encasement, Arch and Cradle Details |
| 4 |
Trench/Pavement Restoration Detail |
| 4-2 |
Trench/Pavement Restoration Detail (Page 2) |
| 5A |
Thrust Block Detail |
| 5B |
Thrust Block Detail |
| 5C |
Thrust Block Detail |
| 6 |
Restrained Joint Table Detail |
| 7 |
Concrete Pipe Support Detail |
| 8 |
Tie Back Assembly Detail |
| 9A |
Option “A” Boring & Jacking Water/Sanitary Forcemain or Reuse Main Detail |
| 9B |
Option “B” Direction Bored Water/Sanitary Forcemain or Reuse Main Detail |
| 10A |
Valve Box Collar Details with ID Disk |
| 10B |
Gate Valve and Box Detail |
| 11A |
Air Release Valve Detail |
| 11B |
Air Release Valve Detail with Vent offset |
| 12 |
Manual Air Release Assemble Detail |
| 13 |
Deflection of Pipe Detail at Utility Crossing by Joint Deflection |
| 14 |
Stormwater Pollution Prevention Plan |
| Sanitary Sewer Pump / Lift Station Details |
| LS-1 |
Typical Lift/Pump Station Detail |
| LS-2A |
Landscape Plan Detail |
| LS-2B |
Driveway and Gravel Pad Detail |
| LS-2C |
Shrub Planting and Multi-Trunk Tree Detail |
| LS-2D |
Plant Schedule |
| LS-2E1 |
Landscape Specifications (Page 1) |
| LS-2E2 |
Landscape Specifications (Page 2) |
| LS-2E3 |
Landscape Specifications (Page 3) |
| LS-2E4 |
Landscape Specifications (Page 4) |
| LS-2E5 |
Landscape Specifications (Page 5) |
| LS-3 |
Fence Detail |
| LS-3A |
Gate Detail |
| LS-3B |
Column Alternatives Detail |
| LS-3C |
Fence Attachment to Column Detail |
| LS-3D |
Stucco Finish Detail |
| LS-3E |
Stucco and Brick Finish Detail |
| LS-4 |
Meter & Disconnect Electrical Installation Detail |
| LS-5 |
Pump Station Control Panel Installation Detail |
| LS-6 |
Parts List of a Typical Lift Station Control Panel Support and J-box assemble |
| LS-7 |
Duplex Control Panel Enclosure Dead Front Layout Detail |
| LS-7A |
DS 200 AMP Inlet Detail |
| LS-7B |
200 AMP Angle Adaptor Detail |
| LS-7C |
200 AMP Plug Cap Detail |
| LS-8 |
Duplex Control Panel Enclosure, Subpanel Layout Detail |
| LS-9 |
Pump Station Control Panel Ledger |
| LS-10A |
Duplex Control Schematic 230 Volt/3 Phase 4 Wire Schematic Detail |
| LS-10B |
Duplex Control Schematic 460 Volt/3 Phase/4 Wire Schematic Detail |
| LS-11 |
Junction Box Terminal Strip Mounting Panel |
| LS-12 |
Junction Box Terminal Strip Wiring Schematic Diagram |
| LS-13 |
RTU Antenna/Mast Installation for Lift Station |
| Sanitary Sewer Details |
| S-1A |
Gravity Sewer Manhole Details |
| S-1B |
Doghouse Pre-cast Manhole Detail |
| S-2 |
Manhole Connection Details |
| S-3 |
Sewer Service Lateral Details |
| S-5 |
Grease, Oil, and Sand Interceptor Detail |
| S-6 |
Suburbanaer System, on site Interceptor Tank Installation |
| S-7 |
Suburbanaer System Interceptor Tank Typical Detail |
| S-8 |
Suburbanaer System Tank Installation Details |
| S-9 |
Suburbanaer System Pump Chamber Detail |
| S-10 |
Suburbanaer System Typical Wiring Schematic Diagram |
| S-11 |
Suburbanaer System Typical Service Line Tap to Main Detail |
| S-12 |
Suburbanaer System Typical Station Cleanout and Air Relief Detail |
| S-13 |
Parking Lot/Paved Area Sewer Clean Out Detail |
| Water System Details |
| W-1 |
Temporary Jumper Connection Detail |
| W-2 |
Water Main Blow-off Valve (Manual) and Box Detail |
| W-3 |
Fire Hydrant Assembly Detail |
| W-6 |
Typical Residential Service Connection |
| W-7A |
Single Family Residential Backflow and Water Meter Assembly Low Health Hazard |
| W-7B |
Single Family Residential Backflow and Water Meter Assembly High Health Hazard |
| W-9 |
Approved Water Tanker Truck Backflow Prevention |
| W-10 |
2" and Smaller Combination Meter and Reduced Pressure or Double Check Backflow Preventer |
| W-11 |
3" and Larger Combination Master Meter & Backflow Preventer |
| W-12 |
3" and Larger Parallel Backflow Prevention Assembly |
| W-13 |
Double Check Valve Backflow Preventer with Detector Assembly for Fire Lines |
| W-14 |
Post Indicator Gate Valve (PVI) and Twin Hose Connector Detail |
^Top
|